Operators coming from LibreNMS expect the same figures under a port
graph. Add them:
- Totals: bytes transferred in and out over the selected range
(GraphResponse.totals), integrated from the average rate across the
stitched raw and hourly tiers without double counting; partial
coverage is flagged.
- Summaries read Now / Avg / Max / 95th / Total per direction, plus an
aggregate (in+out) 95th (p95.aggregate_bps, hot store only).
- Utilisation as a percentage of port speed, and a "% of speed" axis.
- "Compare previous period" overlay on the graph view and expanded row.
- Errors and discards graphs (GET /api/v1/graph/counters), hot-store
range only since they have no rollups. Packet and broadcast/multicast
graphs stay disabled: those counters are not polled (DEVIATIONS 56).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_017TuKgyKve2XLFtrrXWMi2w
The owner wants LibreNMS-like 5-minute polling by default and the option
to poll a given device faster or slower. Devices gain poll_interval_s
(new migration; 0 means the default, otherwise 30 to 3600 s), settable in
the device edit dialog and through PUT /api/v1/devices/{slug}; the
poller picks it up on the next inventory refresh.
Everything that assumed one-minute samples now follows the device's
interval: graph and p95 rate windows are at least two polls, the max
series uses irate, the up-series lookback, the no_data warning, the
"unheard of for three polls" fallback and the rollup's thin-window check.
interface_errors widens to 10 m. profiletest keeps 60 s because the
expect budgets are keyed by the 1m group. Recorded as DEVIATIONS 49.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_017TuKgyKve2XLFtrrXWMi2w