Profiles gain category/label/of/display/scale_by/sentinels/enum_state and component_attrs;
every pollable non-interface metric is annotated and an orphan test enforces it. New routes
GET /devices/{slug}/metrics, /metrics/graph and /printers; printer supply type/colour read at
discovery into device_components.attrs; printer_supply_empty alert; supply_replaced audit event;
docs/coverage.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Lx9FNLG2CqeBbVGGd9bFsP
5.7 KiB
Collection coverage
What the spec's "What to collect, by device class" table (docs/spec/spec.md) asks for, against what the shipped
profiles in profiles/ collect today. A metric listed here is polled, stored raw and shown on a device tab (every
non-interface metric names a category; the orphan test in internal/profile/present_test.go enforces it). Gaps are
stated plainly; nothing here is promised that is not collected.
Legend: yes collected and shown; partial some of it; no not collected.
| Class | Spec item | Status | Profile and metric |
|---|---|---|---|
| Every device | sysUpTime | yes | generic: sysUpTime, hrSystemUptime |
| Every device | hrProcessorLoad per core | yes | generic: hrProcessorLoad |
| Every device | hrStorage size/used per filesystem and RAM | yes | generic: hrStorageUsed / hrStorageSize x hrStorageAllocationUnits (bytes, percent bar) |
| Every device | memTotalReal / memAvailReal (UCD) | yes | generic: memTotalReal, memAvailReal |
| Servers | UCD load average | yes | linux-netsnmp, ubiquiti-edgeos: laLoadInt |
| Servers | swap | yes | linux-netsnmp: memTotalSwap, memAvailSwap |
| Routers, switches | IF-MIB counters, ifOperStatus | yes | generic (Ports tab) |
| Routers, switches | ENTITY-SENSOR-MIB temp/fan/PSU | partial | generic entPhySensorValue is the raw reading only: its type, scale and precision are not applied, so units are mixed (environment tab, labelled raw). No fan or PSU state. cisco-ios/cisco-nxos entSensorValue is the same |
| Routers, switches | POWER-ETHERNET-MIB PoE per port | no | not in any profile |
| Routers, switches | LLDP neighbours | yes | generic discovery table only (no metric) |
| Routers, switches | BGP-4-MIB peer state and prefixes | no | the routing category exists but no profile fills it |
| Routers, switches | optics DOM | partial | juniper-junos jnxDom* are collected but are interface metrics, so they are not on a device tab (there is no optics tab data yet); cisco entSensor DOM is not separated from the raw sensor reading |
| Routers, switches | STP topology changes | no | |
| Routers, switches | MAC/ARP table size | no | |
| Routers, switches | cpmCPUTotal, jnxOperatingCPU | yes | cisco-ios, cisco-nxos: cpmCPUTotal5minRev; juniper-junos: jnxOperatingCPU, jnxOperatingTemp, jnxOperatingBuffer |
| Routers, switches | Cisco memory pools | yes | cisco-ios: ciscoMemoryPoolUsed / Free (not as a percent; there is no total) |
| Switches (Ubiquiti) | memory | partial | ubiquiti-edgeswitch, ubiquiti-unifi-switch: free / available only; CPU is a text string in that MIB and is not collected |
| Firewalls | session count | partial | fortigate: fgSysSesCount (no maximum); pfsense has no vendor metrics |
| Firewalls | VPN tunnel state | no | |
| Firewalls | HA state | partial | fortigate: fgHaSystemMode only |
| Firewalls | policy throughput (fgSys, panSession, pfSense) | no | fortigate CPU and memory only |
| APs, controllers | client count per AP and SSID | yes | ubiquiti-unifi-ap: unifiVapNumStations per SSID |
| APs, controllers | channel utilization | yes | ubiquiti-unifi-ap: unifiRadioCu* per radio |
| APs, controllers | noise floor | no | the UniFi MIB has no such object |
| APs, controllers | tx power | yes | ubiquiti-unifi-ap: unifiVapTxPower |
| APs, controllers | AP up/down from controller | no | no controller integration |
| WISP radios, CPE | signal, SNR, modulation, link capacity | no | no Ubiquiti airMAX, Cambium or Mimosa profile |
| Servers, hypervisors | Proxmox push | yes | push receiver and the proxmox integration (not a profile) |
| Servers, hypervisors | node_exporter, Ceph, SMART | no | |
| UPS, PDU | battery charge, runtime, input/output voltage, load, output status | yes | apc-ups: UPS-MIB and PowerNet upsAdv/upsBasic metrics (power tab) |
| UPS, PDU | per-outlet current (PDU MIBs), generator status | no | |
| Printers | supply levels per prtMarkerSupplies | yes | printer: prtMarkerSuppliesLevel of prtMarkerSuppliesMaxCapacity; -3 "some remaining" and -2 "unknown" are stored and shown as words |
| Printers | supply type and colour | yes | printer: prtMarkerSuppliesType and prtMarkerColorantValue, read at discovery as component attributes |
| Printers | page count | yes | printer: prtMarkerLifeCount |
| Printers | status and alerts | partial | printer: prtAlertSeverityLevel (severity only, not the alert description or code) |
| Printers | paper tray levels | yes | printer: prtInputCurrentLevel of prtInputMaxCapacity, labelled by prtInputName |
| Printers | hp, Brother, Xerox serial and model | no | serial and model are not collected; no vendor quirk profiles (printer-brother, printer-ricoh) are shipped, see below |
| Environment | ENTITY-SENSOR-MIB | partial | as for routers: raw reading only |
| Environment | temperature, humidity, door, water (NetBotz, Raritan) | no | no profile |
| Environment | MikroTik health | yes | mikrotik-routeros: voltage, board and CPU temperature |
| Services | ping, HTTP, DNS, TLS expiry | yes | checks (not profiles) |
Profiles with no vendor metrics beyond generic: arista-eos, pfsense, vyos, windows-snmp.
Alerts named in the spec
| Alert | Status |
|---|---|
| cpu_high, memory_high, disk_full | yes |
| ups_on_battery, ups_runtime_low | yes |
| printer_supply_low (< 10%) | yes |
| printer_supply_empty (level 0, critical) | yes (added in v1.0.1) |
| temp_high (per-profile threshold) | yes, for MikroTik, UPS battery and Junos sensors only |
| "any prtAlert of severity critical" | no rule; prtAlertSeverityLevel is collected and shown, not alerted on |
Printer quirk profiles (Brother, Ricoh)
Not shipped. The LibreNMS recordings (tests/snmpsim/brother*.snmprec, ricoh*.snmprec) were not used to derive a
quirk set, so none is claimed. The generic printer profile matches Brother (2435) and Ricoh (367) by enterprise number.